| Input |
nput : 90 VAC - 130 VAC or 180 VAC - 260 VAC |
| Output |
(Max. output power 230 W at 30ºC)
|
Voltage
|
Min.load
|
Rated Load
|
Max. Load
|
Voltage Accessory
|
|
+5V
|
4.0 A
|
20 A
|
25 A
|
4.80 V to 5.20 V
|
|
+12V
|
1.0 A
|
10 A
|
12 A
|
11.4 V to 12.9 V
|
|
-12V
|
0.1 A
|
0.5 A
|
1 A
|
-11.30 V to -12.60 V
|
|
-5 V
|
0.1 A
|
0.5 A
|
1 A
|
-4.65 V to -5.25 V
|
|
| Ripple and Noise |
The peak to peak ripple and noise for the +5 V output is less than 50 mV,for the +/-12 V and -5 V output it's less than 100 mV. |
| Line Regulation |
The line regulation for each output is less +/- 1% while measuring at rated load and +/-10% or 115VAC or 230VAC input voltage changing. |
| Load Regulation |
The output voltage load regulation is less than the following values when changing each output and 40% to 60% rated load, with all other outputs at 60% of the rated load.
| +5V:+/-4% |
+12V:+/-5% |
-12V:+/-5% |
-5V:+/-2% |
|
| Watt |
230W |
| Hold-up Time |
>16ms |
| Efficiency |
70% typical |
| Protection |
Output protection: Overvoltage and short protection |
| MTBF |
122,347 Hrs |
| Safety |
CSA22.2 No. 234; |
| EMI |
ECC docket 20780 curve"B" ; EN55022 class "B" |
| Power good signal |
Go high 100ms to 500ms after all output DC Voltages are within regulation limits. |
| Power connectors |
DIN 41612 C96 |
| Storage Temperature |
-40 ºC~ 75ºC |
| Operation Temperature |
0 ºC~ 50ºC(derating about 20% form 30ºC to 50ºC) |
| Dimensions |
140 x 150 x 86mm |
| Pin |
Pin Assignment:
|
Pin 1
|
AC L
|
Pin 11, 12, 13
|
+12V
|
|
4
|
AC N
|
11~25
|
GND
|
|
9
|
-5 V
|
26~31
|
+5V
|
|
10
|
-12V
|
32
|
Power good
|
|
| Cooling |
Cooling with a 42CFM fan |